Description
General Specifications*
Operating Temperature
-40° to 80°C (-40°F to 176°F).
Accuracy
Voltage output ±4% (full scale) of visual dial indication. (Float gauge errors not included.) See DS-1318 for nominal output voltages corresponding with dial graduations.
Repeatability
±1%.
Operational Voltage Range
3.5 to 6.0 vdc/ratiometric.
Output Voltage
Ratiometric 5-80% of input voltage @ 5-80% volume.
Resolution
Infinite.
Operating Current
4.5 mA.
Output Current
±1 MA.
Hall Effect modules are UL Classified as intrinsically safe for Class 1, Division 1, Groups C & D (Hazardous Locations). See WD-570 for control drawing.
When Ordering Specify:
1. Junior, Senior or Snap-on; Horizontal, Vertical or Below Ground tank.
2. Or part number.
*Materials and specifications are subject to change without notice. Pressure ratings subject to change due to temperature and other environmental considerations.
WARNING! This sensor is not to be used as the primary means of determining high or low fuel condition. It must not be used in the absence of
redundant systems in critical applications where there may be significant safety risk or financial exposure in the event of fuel overfill or fuel exhaustion
condition. This sensor is not to be used for tank filling.
Materials of Construction*
Crystal & Case
Polycarbonate.
Dial
Painted aluminum.
How to Order
Remote Ready Dial (R3D®)
Part Number | Style | Tank |
---|---|---|
5909s02733 | Jr. | Horizontal |
5986s02733 | Sr. | |
5AAAs02733 | Snap-On | |
5909s02772 | Jr. | Vertical DOT |
5909s02799 | Jr. | Below Ground |
Hall Effect Components**
Model | Style | Wires |
---|---|---|
9700-00005 | Hall Effect Module Kit: Housing, PCB, Vertical Potting Cap | N/A |
9701-00014 | Hall Effect Modul Potted (Vertical) | 6 Feet |
9701-00048 | Hall Effect Modul Potted (Vertical) w/ Packard connector (15336029) | 5 Feet |
0023-00537 | Straight Potting Cap | N/A |
0023-00535 | Vertical Potting Cap | N/A |
**Hall Effect Components only available through remote monitor OEM’s.
Warning! For LP-gas and other flammable product service applications, connect only to circuits and power sources Classified and labeled as Intrinsically Safe for Class 1, Division 1, Group C and D hazardous locations. The connection of non-intrinsically safe power could cause fire or explosion of flammable vapor which may be present.