Descripción
Especificaciones generales *
Mounting
Designed for mounting on flat ends of horizontal, cylindrical farm tanks.
Accuracy
Accuracy depends upon proper gauge sizing and is typically ±5% of dial indication. Accuracy may be less for some tank shapes and sizes. Accuracy may be less near full and empty. Accuracy may be less if tank is not level. This gauge is not to be used for filling. All accuracy estimates are expressed as a percent of full scale.
Temperature
Standard operating range is -40°F to 158°F, -40°C to 70°C.
Humidity
Exposed portion suitable for outdoor applications.
Shock
Suitable for mobile applications.
Vibration
Suitable for mobile applications.
Tank Pressure
0 to 10 PSIG [0 to 0,68 Bar].
Approvals
U.L. listed for flammable liquids.
Materiales de construcción *
Head
Aluminum die-casting.
Support Tube & Float Rod
Aluminum.
Drive Magnet
Alnico.
Bearings
Stainless steel.
Float
Nitrile rubber.
Dial
Aluminum with acrylic crystal.
Al ordenar especifique:
1. Gauge model number.
2. Tank height.
3. Stationary or mobile application.
4. Any special requirements*.
* Los materiales y especificaciones están sujetos a cambios sin previo aviso. Las clasificaciones de presión están sujetas a cambios debido a la temperatura y otras consideraciones medioambientales.