Description
Dimensions
Probe Lengths: 500mm, 1,000mm for cutting to length by customer.
Threads: ½” BSPT, 1” BSPT, ½” NPT
Optional Flange: SAE 5 Hole: Fozmula F/T1 for ½” BSPT
Fozmula F/T8 for ½” NPT
Performance
Performance: Accuracy: ±2% of depth @ 20 ºC
Materials
Enclosure: 30% glass filled nylon
Internal Electrode: Aluminium alloy 6063
Sensor Tube: 316 stainless steel
Wetted Seals: Viton, NBR
Internal Spacers: Polypropylene
End plug: PVC / G/F nylon
Environmental Ratings
Sealing: IP67 with mating connector
Max Pressure: 1 bar
Operating Temp: -20 ºC to +85 ºC
Shock: 50 g, 6.3 ms
Vibration: 7.6 Grms
BS EN 60068-2-64:1993
Weight: 300 g (1 m long sensor)
Electrical
Supply Voltage: 9-34 VDC
Supply Current: 30 mA
Supply Protection: Over-voltage 80 VDC for 2 minutes.
Reverse polarity.
Signal Output: Resistance range; 0-250 Ω or 250-0 Ω, 2 Ω steps, 0.4 W max.
Voltage source range; 0-5 V or 5-0 V, 20 mV steps, 10 mA max.
Alarm Output: Switch to ground, close on fall at 12.5% of active length. Max 100 mA.
Connections: 4 Way Delphi Packard Metri-Pack 150 Series.
Mating Connector: Fozmula C/K1 (Delphi Packard Metri-Pack 150)
To fit 0.8-1.0 mm2 conductor, Ø1.6-2.15 mm sleeve.
Calibration Instructions
Units will be supplied calibrated for diesel.
Full Point:
- Install sensor in the tank and power on.
- Fill tank to required full level.
- Depress “CAL” button. Hold for 5 seconds to set full point. Release button. Check output for full point.
Calibration Instructions
Empty Point (if required):
- Fill tank to required level or, for Min. Empty Level, remove from tank and shake to remove excess liquid.
- Disconnect power.
- Depress “CAL” button then reconnect power whilst depressing calibration button. Continue to depress for a further 5 seconds to set empty point. Release button. Check output for empty point.