Description
Liquid types
Water based liquids such as coolant or washer fluid.
Electrical rating
Supply voltage: 5±0.25 VDC.
Supply current: 5mA + source output.
Alarm delay time: 0 to 25s rising or falling(factory set).
Connection: 3way Packard Metripack 150 connector.
Power up delay: 0to 10 s(factory set).
Power up state: ‘In Liquid’ or ‘Out of Liquid'(factory set).
Output type: Voltage.
Output pin: PinB.
Output state in liquid*: 1.2±0.25 VDC
Output state in air*: 3.75±0.25 VDC
Output current: 10 mAmaximum.
Environmental Ratings
Ingress: IP67(with mating connector fitted).
Max. pressure: 5.0 Bar (72 psi)
Temp. range: -40°C to +125°C (-40 ºF to + 257ºF)
Weight: 70g typical (dependent on thread size)
EMC: ISO13766:2006
Construction
Body: Brass.
Probe: PTFE.
Terminals: Brass, Tin Plated.
Seals: EPDM & FVMQ.
Connector: PA66 30% Glass Filled Nylon.
Thread sealant: Vibra-Seal 516 (taper thread variants only).
Vibration (15.3Grms): 3 orthogonal planes for 3 hours per plane
Testing performed in accordance with BSEN 60068-2-64:1993
Drop: 1 m to concrete surface.
Connections
See diagram below.*Outputs are factory selectable; opposite states and alternative values from 0.5-4.5 VDC are available on request.
Optional accessories
Packard Metri-Pack 150 series mating connector kit to suit harness wire cross sectional area of 0.8 to 1.0mm2and sleeve Ø1.60 to 2.15mm.