Description
Liquid types
Water based liquids such as coolant or washer fluid.
Electrical rating
Supply voltage: 9-36 VDC.
Supply current: 7 mA + source output.
Max. load current: 20 mA (source).
Alarm delay time: 0 to 25 s rising or falling (factory set).
Connection: 4 way Delphi Packard Metri-Pack 150 series connector.
Power up delay: 0 to 10 s (factory set).
Power up state: ‘In Liquid’ or ‘In Air’ (factory set).
Output type: Source (supply voltage less typically 2.7 V @ 10 mA).
Output pin: Pin D.
Output state: Source On / Off in liquid (factory set).
Connections
See diagram below
Optional accessories
C/K1: Packard Metri-Pack 150 series mating connector kit to suit harness wire cross sectional area of 0.8 to 1.0 mm2 and sleeve Ø1.60 to 2.15 mm.
Construction
Body: Brass.
Probe: PTFE
Terminals: Brass, Tin Plated.
Seals: EPDM & FVMQ.
Connector: PA66 30% Glass Filled Nylon.
Thread sealant: Vibra-Seal 516 (taper thread variants only).
Vibration (15.3 Grms): 3 orthogonal planes for 3 hours per plane
Testing performed in accordance with BSEN 60068-2-64:1993
Drop: 1 m to concrete surface.